W12X136 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 13.40 | in (340.4 mm) |
| Flange Width (bf) | 12.40 | in (315.0 mm) |
| Flange Thickness (tf) | 1.25 | in |
| Web Thickness (tw) | 0.79 | in |
| Area (A) | 39.90 | in² (257.4 cm²) |
| Weight | 136 | lb/ft (202 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 1,240 | 398 | in⁴ |
| Elastic Section Modulus (S) | 186 | 64.20 | in³ |
| Plastic Section Modulus (Z) | 214 | 98 | in³ |
| Radius of Gyration (r) | 5.58 | 3.16 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 18.50 | in⁴ |
| Warping Constant (Cw) | 14,700 | in⁶ |
| Distance Between Flange Centroids (ho) | 12.20 | in |
| Effective Radius (rts) | 3.61 | in |
Design Resources
- Beam Capacity Calculator — Check W12X136 for your span and loads
- Column Capacity Calculator — Check W12X136 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W12X136 beam? 136 lb/ft (202 kg/m). A 40-ft length weighs approximately 5,440 lbs.
What is the section modulus of W12X136? Sx = 186 in³ (strong axis) and Sy = 64.2 in³ (weak axis). The plastic section modulus Zx = 214 in³ and Zy = 98 in³.
What steel grade is standard for W12X136? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.