W12X136 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 13.40 in (340.4 mm)
Flange Width (bf) 12.40 in (315.0 mm)
Flange Thickness (tf) 1.25 in
Web Thickness (tw) 0.79 in
Area (A) 39.90 in² (257.4 cm²)
Weight 136 lb/ft (202 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 1,240 398 in⁴
Elastic Section Modulus (S) 186 64.20 in³
Plastic Section Modulus (Z) 214 98 in³
Radius of Gyration (r) 5.58 3.16 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 18.50 in⁴
Warping Constant (Cw) 14,700 in⁶
Distance Between Flange Centroids (ho) 12.20 in
Effective Radius (rts) 3.61 in

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 1,240 in⁴, the strong-axis stiffness places it in the heavy beam category for preliminary sizing.

At 13.4" deep and 136 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 10,700 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 1,240 in⁴
Torsion St. Venant = GJ/L J = 18.5 in⁴
Column buckling KL/r → Fcr r_x = 5.58 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Library stack beam — w12x136

Scenario: Library stack area — dead load includes shelving and books. Simply supported wide flange, 25 ft span, 7 ft tributary width. Service loads: 85 psf dead + 60 psf live (1015 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (420/12) × (300)⁴ / (384 × 29,000,000 × 1,240)

Δ_LL = 0.10 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 300 / 240 = 1.25 in

Step 3 — Dead + live deflection:

Δ_total = 0.25 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 803 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.