W12X19 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 12.20 | in (309.9 mm) |
| Flange Width (bf) | 4.01 | in (101.9 mm) |
| Flange Thickness (tf) | 0.35 | in |
| Web Thickness (tw) | 0.23 | in |
| Area (A) | 5.57 | in² (35.9 cm²) |
| Weight | 19 | lb/ft (28 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 130 | 3.76 | in⁴ |
| Elastic Section Modulus (S) | 21.30 | 1.88 | in³ |
| Plastic Section Modulus (Z) | 24.70 | 2.98 | in³ |
| Radius of Gyration (r) | 4.82 | 0.82 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 0.18 | in⁴ |
| Warping Constant (Cw) | 131 | in⁶ |
| Distance Between Flange Centroids (ho) | 11.90 | in |
| Effective Radius (rts) | 1.02 | in |
Design Resources
- Beam Capacity Calculator — Check W12X19 for your span and loads
- Column Capacity Calculator — Check W12X19 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W12X19 beam? 19 lb/ft (28 kg/m). A 40-ft length weighs approximately 760 lbs.
What is the section modulus of W12X19? Sx = 21.3 in³ (strong axis) and Sy = 1.9 in³ (weak axis). The plastic section modulus Zx = 24.7 in³ and Zy = 3.0 in³.
What steel grade is standard for W12X19? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.