W12X19 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 12.20 in (309.9 mm)
Flange Width (bf) 4.01 in (101.9 mm)
Flange Thickness (tf) 0.35 in
Web Thickness (tw) 0.23 in
Area (A) 5.57 in² (35.9 cm²)
Weight 19 lb/ft (28 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 130 3.76 in⁴
Elastic Section Modulus (S) 21.30 1.88 in³
Plastic Section Modulus (Z) 24.70 2.98 in³
Radius of Gyration (r) 4.82 0.82 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.18 in⁴
Warping Constant (Cw) 131 in⁶
Distance Between Flange Centroids (ho) 11.90 in
Effective Radius (rts) 1.02 in

Section Profile Summary

With Ix = 130 in⁴, this wide flange is a practical choice for short-span beams, lintels, and secondary framing members.

At 12.2" deep and 19 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 1,235 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 130 in⁴
Torsion St. Venant = GJ/L J = 0.18 in⁴
Column buckling KL/r → Fcr r_x = 4.82 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Light commercial floor beam — w12x19

Scenario: Retail space floor — higher live load for public occupancy. Simply supported wide flange, 23 ft span, 8 ft tributary width. Service loads: 55 psf dead + 60 psf live (920 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (480/12) × (276)⁴ / (384 × 29,000,000 × 130)

Δ_LL = 0.80 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 276 / 240 = 1.15 in

Step 3 — Dead + live deflection:

Δ_total = 1.54 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 93 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.