W14X22 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 13.70 | in (348.0 mm) |
| Flange Width (bf) | 5 | in (127.0 mm) |
| Flange Thickness (tf) | 0.34 | in |
| Web Thickness (tw) | 0.23 | in |
| Area (A) | 6.49 | in² (41.9 cm²) |
| Weight | 22 | lb/ft (33 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 199 | 7 | in⁴ |
| Elastic Section Modulus (S) | 29 | 2.80 | in³ |
| Plastic Section Modulus (Z) | 33.20 | 4.39 | in³ |
| Radius of Gyration (r) | 5.54 | 1.04 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 0.21 | in⁴ |
| Warping Constant (Cw) | 314 | in⁶ |
| Distance Between Flange Centroids (ho) | 13.40 | in |
| Effective Radius (rts) | 1.27 | in |
Design Resources
- Beam Capacity Calculator — Check W14X22 for your span and loads
- Column Capacity Calculator — Check W14X22 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W14X22 beam? 22 lb/ft (33 kg/m). A 40-ft length weighs approximately 880 lbs.
What is the section modulus of W14X22? Sx = 29 in³ (strong axis) and Sy = 2.8 in³ (weak axis). The plastic section modulus Zx = 33.2 in³ and Zy = 4.4 in³.
What steel grade is standard for W14X22? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.
What is the moment of inertia of W14X22? Ix = 199 in⁴ about the strong axis and Iy = 7 in⁴ about the weak axis. The radius of gyration is rx = 5.54 in and ry = 1.04 in.
Related Pages
- Steel Beam Sizes Reference
- Beam Capacity Calculator
- Column Capacity Calculator
- Section Properties Database
Educational reference only. Verify all section properties against the current AISC Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.