W14X68 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 14 | in (355.6 mm) |
| Flange Width (bf) | 10 | in (254.0 mm) |
| Flange Thickness (tf) | 0.72 | in |
| Web Thickness (tw) | 0.41 | in |
| Area (A) | 20 | in² (129.0 cm²) |
| Weight | 68 | lb/ft (101 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 722 | 121 | in⁴ |
| Elastic Section Modulus (S) | 103 | 24.20 | in³ |
| Plastic Section Modulus (Z) | 115 | 36.90 | in³ |
| Radius of Gyration (r) | 6.01 | 2.46 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 3.01 | in⁴ |
| Warping Constant (Cw) | 5,380 | in⁶ |
| Distance Between Flange Centroids (ho) | 13.30 | in |
| Effective Radius (rts) | 2.80 | in |
Design Resources
- Beam Capacity Calculator — Check W14X68 for your span and loads
- Column Capacity Calculator — Check W14X68 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W14X68 beam? 68 lb/ft (101 kg/m). A 40-ft length weighs approximately 2,720 lbs.
What is the section modulus of W14X68? Sx = 103 in³ (strong axis) and Sy = 24.2 in³ (weak axis). The plastic section modulus Zx = 115 in³ and Zy = 36.9 in³.
What steel grade is standard for W14X68? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.
What is the moment of inertia of W14X68? Ix = 722 in⁴ about the strong axis and Iy = 121 in⁴ about the weak axis. The radius of gyration is rx = 6.01 in and ry = 2.46 in.
Related Pages
- Steel Beam Sizes Reference
- Beam Capacity Calculator
- Column Capacity Calculator
- Section Properties Database
Educational reference only. Verify all section properties against the current AISC Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.