Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 14.20 | in (360.7 mm) |
| Flange Width (bf) | 14.60 | in (370.8 mm) |
| Flange Thickness (tf) | 0.78 | in |
| Web Thickness (tw) | 0.48 | in |
| Area (A) | 29.10 | in² (187.8 cm²) |
| Weight | 99 | lb/ft (147 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 1,110 | 402 | in⁴ |
| Elastic Section Modulus (S) | 157 | 55.20 | in³ |
| Plastic Section Modulus (Z) | 173 | 83.60 | in³ |
| Radius of Gyration (r) | 6.17 | 3.71 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 5.37 | in⁴ |
| Warping Constant (Cw) | 18,000 | in⁶ |
| Distance Between Flange Centroids (ho) | 13.40 | in |
| Effective Radius (rts) | 4.14 | in |
Design Resources
- Beam Capacity Calculator — Check W14X99 for your span and loads
- Column Capacity Calculator — Check W14X99 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W14X99 beam? 99 lb/ft (147 kg/m). A 40-ft length weighs approximately 3,960 lbs.
What is the section modulus of W14X99? Sx = 157 in³ (strong axis) and Sy = 55.2 in³ (weak axis). The plastic section modulus Zx = 173 in³ and Zy = 83.6 in³.
What steel grade is standard for W14X99? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.
What is the moment of inertia of W14X99? Ix = 1110 in⁴ about the strong axis and Iy = 402 in⁴ about the weak axis. The radius of gyration is rx = 6.17 in and ry = 3.71 in.