W16X40 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 16 in (406.4 mm)
Flange Width (bf) 7 in (177.8 mm)
Flange Thickness (tf) 0.51 in
Web Thickness (tw) 0.30 in
Area (A) 11.80 in² (76.1 cm²)
Weight 40 lb/ft (60 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 518 28.90 in⁴
Elastic Section Modulus (S) 64.70 8.25 in³
Plastic Section Modulus (Z) 73 12.70 in³
Radius of Gyration (r) 6.63 1.57 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.79 in⁴
Warping Constant (Cw) 1,730 in⁶
Distance Between Flange Centroids (ho) 15.50 in
Effective Radius (rts) 1.86 in

Section Profile Summary

Hot-rolled W-shape with Sx = 64.7 in³. The section is appropriate for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 16" deep and 40 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 3,650 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 518 in⁴
Torsion St. Venant = GJ/L J = 0.79 in⁴
Column buckling KL/r → Fcr r_x = 6.63 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital corridor beam — w16x40

Scenario: Hospital corridor — deflection limit tightened for ceiling and services. Simply supported wide flange, 27 ft span, 6 ft tributary width. Service loads: 50 psf dead + 80 psf live (780 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (480/12) × (324)⁴ / (384 × 29,000,000 × 518)

Δ_LL = 0.38 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/360):

Δ_allow = L / 360 = 324 / 360 = 0.90 in

Step 3 — Dead + live deflection:

Δ_total = 0.62 in

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 274 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.