W18X258 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 21.50 in (546.1 mm)
Flange Width (bf) 11.80 in (299.7 mm)
Flange Thickness (tf) 2.30 in
Web Thickness (tw) 1.28 in
Area (A) 76 in² (490.4 cm²)
Weight 258 lb/ft (384 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 5,510 628 in⁴
Elastic Section Modulus (S) 514 107 in³
Plastic Section Modulus (Z) 611 166 in³
Radius of Gyration (r) 8.53 2.88 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 103 in⁴
Warping Constant (Cw) 57,600 in⁶
Distance Between Flange Centroids (ho) 19.20 in
Effective Radius (rts) 3.42 in

Section Profile Summary

With Ix = 5,510 in⁴, this wide flange is commonly specified for long-span floor beams and transfer girders where stiffness controls the design.

At 21.5" deep, this section is frequently specified for primary floor beams, girders, and moment frame columns in commercial and institutional buildings.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 30,550 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 5,510 in⁴
Torsion St. Venant = GJ/L J = 103 in⁴
Column buckling KL/r → Fcr r_x = 8.53 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Residential floor beam — w18x258

Scenario: Residential floor joist supporting bedrooms and living areas. Simply supported wide flange, 43 ft span, 10 ft tributary width. Service loads: 40 psf dead + 40 psf live (800 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (400/12) × (516)⁴ / (384 × 29,000,000 × 5,510)

Δ_LL = 0.19 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/360):

Δ_allow = L / 360 = 516 / 360 = 1.43 in

Step 3 — Dead + live deflection:

Δ_total = 0.39 in

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 2,291 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.