W18X35 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 17.70 in (449.6 mm)
Flange Width (bf) 6 in (152.4 mm)
Flange Thickness (tf) 0.42 in
Web Thickness (tw) 0.30 in
Area (A) 10.30 in² (66.5 cm²)
Weight 35 lb/ft (52 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 510 15.30 in⁴
Elastic Section Modulus (S) 57.60 5.12 in³
Plastic Section Modulus (Z) 66.50 8.06 in³
Radius of Gyration (r) 7.04 1.22 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.51 in⁴
Warping Constant (Cw) 1,140 in⁶
Distance Between Flange Centroids (ho) 17.30 in
Effective Radius (rts) 1.51 in

Section Profile Summary

Hot-rolled W-shape with Sx = 57.6 in³. The section is a practical choice for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 17.7" deep and 35 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 3,325 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 510 in⁴
Torsion St. Venant = GJ/L J = 0.51 in⁴
Column buckling KL/r → Fcr r_x = 7.04 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — w18x35

Scenario: Office floor in a commercial building — typical open-plan layout. Simply supported wide flange, 27 ft span, 8 ft tributary width. Service loads: 50 psf dead + 50 psf live (800 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (400/12) × (324)⁴ / (384 × 29,000,000 × 510)

Δ_LL = 0.32 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 324 / 240 = 1.35 in

Step 3 — Dead + live deflection:

Δ_total = 0.65 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 249 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.