W18X86 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 18.40 in (467.4 mm)
Flange Width (bf) 11.10 in (281.9 mm)
Flange Thickness (tf) 0.77 in
Web Thickness (tw) 0.48 in
Area (A) 25.30 in² (163.2 cm²)
Weight 86 lb/ft (128 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 1,530 175 in⁴
Elastic Section Modulus (S) 166 31.60 in³
Plastic Section Modulus (Z) 186 48.40 in³
Radius of Gyration (r) 7.77 2.63 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 4.10 in⁴
Warping Constant (Cw) 13,600 in⁶
Distance Between Flange Centroids (ho) 17.60 in
Effective Radius (rts) 3.05 in

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 1,530 in⁴, the strong-axis stiffness places it in the heavy beam category for preliminary sizing.

At 18.4" deep and 86 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 9,300 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 1,530 in⁴
Torsion St. Venant = GJ/L J = 4.1 in⁴
Column buckling KL/r → Fcr r_x = 7.77 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Assembly hall floor beam — w18x86

Scenario: Public assembly space — higher live load for movable seating/standing. Simply supported wide flange, 35 ft span, 8 ft tributary width. Service loads: 60 psf dead + 100 psf live (1280 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (800/12) × (420)⁴ / (384 × 29,000,000 × 1,530)

Δ_LL = 0.61 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 420 / 240 = 1.75 in

Step 3 — Dead + live deflection:

Δ_total = 0.97 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 698 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.