W21X68 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 21.10 | in (535.9 mm) |
| Flange Width (bf) | 8.27 | in (210.1 mm) |
| Flange Thickness (tf) | 0.69 | in |
| Web Thickness (tw) | 0.43 | in |
| Area (A) | 20 | in² (129.0 cm²) |
| Weight | 68 | lb/ft (101 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 1,480 | 64.70 | in⁴ |
| Elastic Section Modulus (S) | 140 | 15.70 | in³ |
| Plastic Section Modulus (Z) | 160 | 24.40 | in³ |
| Radius of Gyration (r) | 8.60 | 1.80 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 2.45 | in⁴ |
| Warping Constant (Cw) | 6,760 | in⁶ |
| Distance Between Flange Centroids (ho) | 20.40 | in |
| Effective Radius (rts) | 2.17 | in |
Design Resources
- Beam Capacity Calculator — Check W21X68 for your span and loads
- Column Capacity Calculator — Check W21X68 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W21X68 beam? 68 lb/ft (101 kg/m). A 40-ft length weighs approximately 2,720 lbs.
What is the section modulus of W21X68? Sx = 140 in³ (strong axis) and Sy = 15.7 in³ (weak axis). The plastic section modulus Zx = 160 in³ and Zy = 24.4 in³.
What steel grade is standard for W21X68? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.
What is the moment of inertia of W21X68? Ix = 1480 in⁴ about the strong axis and Iy = 64.7 in⁴ about the weak axis. The radius of gyration is rx = 8.60 in and ry = 1.80 in.
Related Pages
- Steel Beam Sizes Reference
- Beam Capacity Calculator
- Column Capacity Calculator
- Section Properties Database
Educational reference only. Verify all section properties against the current AISC Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.