W27X194 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 28.10 in (713.7 mm)
Flange Width (bf) 14 in (355.6 mm)
Flange Thickness (tf) 1.34 in
Web Thickness (tw) 0.75 in
Area (A) 57.10 in² (368.4 cm²)
Weight 194 lb/ft (289 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 7,860 619 in⁴
Elastic Section Modulus (S) 559 88.10 in³
Plastic Section Modulus (Z) 631 136 in³
Radius of Gyration (r) 11.70 3.29 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 27.10 in⁴
Warping Constant (Cw) 111,000 in⁶
Distance Between Flange Centroids (ho) 26.80 in
Effective Radius (rts) 3.85 in

Section Profile Summary

Hot-rolled W-shape with Sx = 559 in³. The section is suitable for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 28.1" deep, this section is frequently specified for primary floor beams, girders, and moment frame columns in commercial and institutional buildings.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 31,550 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 7,860 in⁴
Torsion St. Venant = GJ/L J = 27.1 in⁴
Column buckling KL/r → Fcr r_x = 11.7 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Parking garage beam — w27x194

Scenario: Parking structure floor beam — asphalt topping included in dead load. Simply supported wide flange, 48 ft span, 9 ft tributary width. Service loads: 80 psf dead + 50 psf live (1170 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (450/12) × (576)⁴ / (384 × 29,000,000 × 7,860)

Δ_LL = 0.24 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 576 / 240 = 2.40 in

Step 3 — Dead + live deflection:

Δ_total = 0.61 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 2,366 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.