W33X130 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 33.10 | in (840.7 mm) |
| Flange Width (bf) | 11.50 | in (292.1 mm) |
| Flange Thickness (tf) | 0.85 | in |
| Web Thickness (tw) | 0.58 | in |
| Area (A) | 38.30 | in² (247.1 cm²) |
| Weight | 130 | lb/ft (193 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 6,710 | 218 | in⁴ |
| Elastic Section Modulus (S) | 406 | 37.90 | in³ |
| Plastic Section Modulus (Z) | 467 | 59.50 | in³ |
| Radius of Gyration (r) | 13.20 | 2.39 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 7.37 | in⁴ |
| Warping Constant (Cw) | 56,600 | in⁶ |
| Distance Between Flange Centroids (ho) | 32.20 | in |
| Effective Radius (rts) | 2.94 | in |
Design Resources
- Beam Capacity Calculator — Check W33X130 for your span and loads
- Column Capacity Calculator — Check W33X130 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W33X130 beam? 130 lb/ft (193 kg/m). A 40-ft length weighs approximately 5,200 lbs.
What is the section modulus of W33X130? Sx = 406 in³ (strong axis) and Sy = 37.9 in³ (weak axis). The plastic section modulus Zx = 467 in³ and Zy = 59.5 in³.
What steel grade is standard for W33X130? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.