W33X201 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 33.70 | in (856.0 mm) |
| Flange Width (bf) | 15.70 | in (398.8 mm) |
| Flange Thickness (tf) | 1.15 | in |
| Web Thickness (tw) | 0.71 | in |
| Area (A) | 59.10 | in² (381.3 cm²) |
| Weight | 201 | lb/ft (299 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 11,600 | 749 | in⁴ |
| Elastic Section Modulus (S) | 686 | 95.20 | in³ |
| Plastic Section Modulus (Z) | 773 | 147 | in³ |
| Radius of Gyration (r) | 14 | 3.56 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 20.80 | in⁴ |
| Warping Constant (Cw) | 198,000 | in⁶ |
| Distance Between Flange Centroids (ho) | 32.60 | in |
| Effective Radius (rts) | 4.21 | in |
Design Resources
- Beam Capacity Calculator — Check W33X201 for your span and loads
- Column Capacity Calculator — Check W33X201 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W33X201 beam? 201 lb/ft (299 kg/m). A 40-ft length weighs approximately 8,040 lbs.
What is the section modulus of W33X201? Sx = 686 in³ (strong axis) and Sy = 95.2 in³ (weak axis). The plastic section modulus Zx = 773 in³ and Zy = 147 in³.
What steel grade is standard for W33X201? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.
What is the moment of inertia of W33X201? Ix = 11600 in⁴ about the strong axis and Iy = 749 in⁴ about the weak axis. The radius of gyration is rx = 14 in and ry = 3.56 in.
Related Pages
- Steel Beam Sizes Reference
- Beam Capacity Calculator
- Column Capacity Calculator
- Section Properties Database