W36X194 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 36.50 | in (927.1 mm) |
| Flange Width (bf) | 12.10 | in (307.3 mm) |
| Flange Thickness (tf) | 1.26 | in |
| Web Thickness (tw) | 0.77 | in |
| Area (A) | 57 | in² (367.8 cm²) |
| Weight | 194 | lb/ft (289 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 12,100 | 375 | in⁴ |
| Elastic Section Modulus (S) | 664 | 61.90 | in³ |
| Plastic Section Modulus (Z) | 767 | 97.70 | in³ |
| Radius of Gyration (r) | 14.60 | 2.56 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 22.20 | in⁴ |
| Warping Constant (Cw) | 116,000 | in⁶ |
| Distance Between Flange Centroids (ho) | 35.20 | in |
| Effective Radius (rts) | 3.15 | in |
Design Resources
- Beam Capacity Calculator — Check W36X194 for your span and loads
- Column Capacity Calculator — Check W36X194 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W36X194 beam? 194 lb/ft (289 kg/m). A 40-ft length weighs approximately 7,760 lbs.
What is the section modulus of W36X194? Sx = 664 in³ (strong axis) and Sy = 61.9 in³ (weak axis). The plastic section modulus Zx = 767 in³ and Zy = 97.7 in³.
What steel grade is standard for W36X194? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.