W36X262 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 36.90 | in (937.3 mm) |
| Flange Width (bf) | 16.60 | in (421.6 mm) |
| Flange Thickness (tf) | 1.44 | in |
| Web Thickness (tw) | 0.84 | in |
| Area (A) | 77.20 | in² (498.1 cm²) |
| Weight | 262 | lb/ft (390 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 17,900 | 1,090 | in⁴ |
| Elastic Section Modulus (S) | 972 | 132 | in³ |
| Plastic Section Modulus (Z) | 1,100 | 204 | in³ |
| Radius of Gyration (r) | 15.30 | 3.76 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 41.60 | in⁴ |
| Warping Constant (Cw) | 342,000 | in⁶ |
| Distance Between Flange Centroids (ho) | 35.50 | in |
| Effective Radius (rts) | 4.46 | in |
Design Resources
- Beam Capacity Calculator — Check W36X262 for your span and loads
- Column Capacity Calculator — Check W36X262 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W36X262 beam? 262 lb/ft (390 kg/m). A 40-ft length weighs approximately 10,480 lbs.
What is the section modulus of W36X262? Sx = 972 in³ (strong axis) and Sy = 132 in³ (weak axis). The plastic section modulus Zx = 1100 in³ and Zy = 204 in³.
What steel grade is standard for W36X262? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.
What is the moment of inertia of W36X262? Ix = 17900 in⁴ about the strong axis and Iy = 1090 in⁴ about the weak axis. The radius of gyration is rx = 15.30 in and ry = 3.76 in.
Related Pages
- Steel Beam Sizes Reference
- Beam Capacity Calculator
- Column Capacity Calculator
- Section Properties Database
Educational reference only. Verify all section properties against the current AISC Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.