W36X723 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 41.80 | in (1061.7 mm) |
| Flange Width (bf) | 17.80 | in (452.1 mm) |
| Flange Thickness (tf) | 3.90 | in |
| Web Thickness (tw) | 2.17 | in |
| Area (A) | 213 | in² (1374.3 cm²) |
| Weight | 723 | lb/ft (1076 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 57,300 | 3,700 | in⁴ |
| Elastic Section Modulus (S) | 2,740 | 416 | in³ |
| Plastic Section Modulus (Z) | 3,270 | 658 | in³ |
| Radius of Gyration (r) | 16.40 | 4.17 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 785 | in⁴ |
| Warping Constant (Cw) | 1,330,000 | in⁶ |
| Distance Between Flange Centroids (ho) | 37.90 | in |
| Effective Radius (rts) | 5.06 | in |
Design Resources
- Beam Capacity Calculator — Check W36X723 for your span and loads
- Column Capacity Calculator — Check W36X723 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W36X723 beam? 723 lb/ft (1076 kg/m). A 40-ft length weighs approximately 28,920 lbs.
What is the section modulus of W36X723? Sx = 2740 in³ (strong axis) and Sy = 416 in³ (weak axis). The plastic section modulus Zx = 3270 in³ and Zy = 658 in³.
What steel grade is standard for W36X723? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.