W40X199 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 38.70 in (983.0 mm)
Flange Width (bf) 15.80 in (401.3 mm)
Flange Thickness (tf) 1.07 in
Web Thickness (tw) 0.65 in
Area (A) 58.80 in² (379.4 cm²)
Weight 199 lb/ft (296 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 14,900 695 in⁴
Elastic Section Modulus (S) 770 88.20 in³
Plastic Section Modulus (Z) 869 137 in³
Radius of Gyration (r) 16 3.45 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 18.30 in⁴
Warping Constant (Cw) 246,000 in⁶
Distance Between Flange Centroids (ho) 37.60 in
Effective Radius (rts) 4.12 in

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 14,900 in⁴, the strong-axis stiffness places it in the heavy beam category for preliminary sizing.

At 38.7" deep and 199 lb/ft, this is a heavy section typically reserved for transfer girders, long-span roof trusses, and heavily loaded columns in high-rise construction. Shipping and handling require crane erection planning.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 43,450 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 14,900 in⁴
Torsion St. Venant = GJ/L J = 18.3 in⁴
Column buckling KL/r → Fcr r_x = 16 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Warehouse mezzanine beam — w40x199

Scenario: Mezzanine beam in a warehouse — storage live load governs design. Simply supported wide flange, 58 ft span, 5 ft tributary width. Service loads: 30 psf dead + 125 psf live (775 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (625/12) × (696)⁴ / (384 × 29,000,000 × 14,900)

Δ_LL = 0.37 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 696 / 240 = 2.90 in

Step 3 — Dead + live deflection:

Δ_total = 0.46 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 3,259 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.