W40X324 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 40.20 in (1021.1 mm)
Flange Width (bf) 15.90 in (403.9 mm)
Flange Thickness (tf) 1.81 in
Web Thickness (tw) 1 in
Area (A) 95.30 in² (614.9 cm²)
Weight 324 lb/ft (482 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 25,600 1,220 in⁴
Elastic Section Modulus (S) 1,280 153 in³
Plastic Section Modulus (Z) 1,460 239 in³
Radius of Gyration (r) 16.40 3.58 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 79.40 in⁴
Warping Constant (Cw) 448,000 in⁶
Distance Between Flange Centroids (ho) 38.40 in
Effective Radius (rts) 4.27 in

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 25,600 in⁴, the strong-axis stiffness places it in the heavy beam category for preliminary sizing.

At 40.2" deep and 324 lb/ft, this is a heavy section typically reserved for transfer girders, long-span roof trusses, and heavily loaded columns in high-rise construction. Shipping and handling require crane erection planning.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 73,000 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 25,600 in⁴
Torsion St. Venant = GJ/L J = 79.4 in⁴
Column buckling KL/r → Fcr r_x = 16.4 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Library stack beam — w40x324

Scenario: Library stack area — dead load includes shelving and books. Simply supported wide flange, 60 ft span, 7 ft tributary width. Service loads: 85 psf dead + 60 psf live (1015 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (420/12) × (720)⁴ / (384 × 29,000,000 × 25,600)

Δ_LL = 0.16 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 720 / 240 = 3.00 in

Step 3 — Dead + live deflection:

Δ_total = 0.40 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 5,475 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.