W40X362 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 40.60 | in (1031.2 mm) |
| Flange Width (bf) | 16 | in (406.4 mm) |
| Flange Thickness (tf) | 2.01 | in |
| Web Thickness (tw) | 1.12 | in |
| Area (A) | 106 | in² (683.9 cm²) |
| Weight | 362 | lb/ft (539 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 28,900 | 1,380 | in⁴ |
| Elastic Section Modulus (S) | 1,420 | 173 | in³ |
| Plastic Section Modulus (Z) | 1,640 | 270 | in³ |
| Radius of Gyration (r) | 16.50 | 3.60 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 109 | in⁴ |
| Warping Constant (Cw) | 513,000 | in⁶ |
| Distance Between Flange Centroids (ho) | 38.60 | in |
| Effective Radius (rts) | 4.33 | in |
Design Resources
- Beam Capacity Calculator — Check W40X362 for your span and loads
- Column Capacity Calculator — Check W40X362 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W40X362 beam? 362 lb/ft (539 kg/m). A 40-ft length weighs approximately 14,480 lbs.
What is the section modulus of W40X362? Sx = 1420 in³ (strong axis) and Sy = 173 in³ (weak axis). The plastic section modulus Zx = 1640 in³ and Zy = 270 in³.
What steel grade is standard for W40X362? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.
What is the moment of inertia of W40X362? Ix = 28900 in⁴ about the strong axis and Iy = 1380 in⁴ about the weak axis. The radius of gyration is rx = 16.50 in and ry = 3.60 in.