W40X397 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 41 | in (1041.4 mm) |
| Flange Width (bf) | 16.10 | in (408.9 mm) |
| Flange Thickness (tf) | 2.20 | in |
| Web Thickness (tw) | 1.22 | in |
| Area (A) | 117 | in² (754.9 cm²) |
| Weight | 397 | lb/ft (591 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 32,000 | 1,540 | in⁴ |
| Elastic Section Modulus (S) | 1,560 | 191 | in³ |
| Plastic Section Modulus (Z) | 1,800 | 300 | in³ |
| Radius of Gyration (r) | 16.60 | 3.64 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 142 | in⁴ |
| Warping Constant (Cw) | 579,000 | in⁶ |
| Distance Between Flange Centroids (ho) | 38.80 | in |
| Effective Radius (rts) | 4.38 | in |
Design Resources
- Beam Capacity Calculator — Check W40X397 for your span and loads
- Column Capacity Calculator — Check W40X397 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W40X397 beam? 397 lb/ft (591 kg/m). A 40-ft length weighs approximately 15,880 lbs.
What is the section modulus of W40X397? Sx = 1560 in³ (strong axis) and Sy = 191 in³ (weak axis). The plastic section modulus Zx = 1800 in³ and Zy = 300 in³.
What steel grade is standard for W40X397? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.