WT5X27 Steel WT-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 5.05 128.3 mm
Flange Width (bf) 10 25.40 cm
Flange Thickness (tf) 0.615 15.6 mm
Web Thickness (tw) 0.37 9.4 mm
Area (A) 7.9 in² 51.0 cm²
Weight 27 lb/ft 40.2 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 11.1 51.7 in⁴
Elastic Section Modulus (S) 2.64 10.3 in³
Plastic Section Modulus (Z) 5.05 15.6 in³
Radius of Gyration (r) 1.19 2.56 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.909 in⁴
Warping Constant (Cw) 1.78 in⁶

Section Profile Summary

The centroid of a tee is closer to the flange, creating an inherent eccentricity in tension connections. For truss chords and bracing, account for this eccentricity in the connection design — the induced bending moment can be significant for slender members.

At 5.05" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 252.5 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 11.1 in⁴
Torsion St. Venant = GJ/L J = 0.909 in⁴
Column buckling KL/r → Fcr r_x = 1.19 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Tension Capacity — wt5x27

Scenario: wt5x27 used as a bottom chord member in a roof truss. The member carries axial tension only under the governing load combination.

Given:

Step 1 — Gross yield (AISC 360 Eq. D2-1):

φTn_yield = 0.9 × Ag × Fy = 0.9 × 7.9 × 50 = 356 kips

Step 2 — Net section fracture:

For bolted connections, deduct bolt holes from Ag: An = Ag − n × dh × tf

The effective net area Ae = U × An depends on the shear lag factor U per AISC 360 Table D3.1.

Check φTn_fracture = 0.75 × Ae × Fu per AISC 360 Eq. D2-2.

Step 3 — Stem-in-tension note:

For WT/ST sections loaded in axial tension, the eccentricity between the centroid and the connection plane introduces a bending moment that should be considered in the connection design. The stem is more flexible than the flange — verify the weld or bolt group can accommodate the induced prying action.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.