C12X25 Steel C-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 12 304.8 mm
Flange Width (bf) 3.05 7.75 cm
Flange Thickness (tf) 0.501 12.7 mm
Web Thickness (tw) 0.387 9.8 mm
Area (A) 7.34 in² 47.4 cm²
Weight 25 lb/ft 37.2 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 144 4.45 in⁴
Elastic Section Modulus (S) 24 1.87 in³
Plastic Section Modulus (Z) 29.4 3.82 in³
Radius of Gyration (r) 4.43 0.779 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.538 in⁴
Warping Constant (Cw) 130 in⁶
Distance Between Flange Centroids (ho) 11.5 in
Effective Radius (rts) 1 in

Section Profile Summary

Channels are efficient for bracing, girts, and stair stringers where loads align near the shear center. At 25 lb/ft, this channel is appropriate for secondary framing in industrial and commercial structures.

At 12" deep, this is a compact section appropriate for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 1,470 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 144 in⁴
Torsion St. Venant = GJ/L J = 0.538 in⁴
Column buckling KL/r → Fcr r_x = 4.43 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Roof beam (flat roof) — c12x25

Scenario: Flat roof beam with mechanical unit allowance — drainage slope not included. Simply supported channel, 24 ft span, 6 ft tributary width. Service loads: 25 psf dead + 20 psf live (270 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (120/12) × (288)⁴ / (384 × 29,000,000 × 144)

Δ_LL = 0.21 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 288 / 240 = 1.20 in

Step 3 — Dead + live deflection:

Δ_total = 0.48 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 110 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.