C15X33.9 Steel C-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 15 381.0 mm
Flange Width (bf) 3.4 8.64 cm
Flange Thickness (tf) 0.65 16.5 mm
Web Thickness (tw) 0.4 10.2 mm
Area (A) 10 in² 64.5 cm²
Weight 33.9 lb/ft 50.4 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 315 8.07 in⁴
Elastic Section Modulus (S) 42 3.09 in³
Plastic Section Modulus (Z) 50.8 6.19 in³
Radius of Gyration (r) 5.61 0.901 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 1.01 in⁴
Warping Constant (Cw) 358 in⁶
Distance Between Flange Centroids (ho) 14.4 in
Effective Radius (rts) 1.13 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 15" deep and 33.9 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 2,540 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 315 in⁴
Torsion St. Venant = GJ/L J = 1.01 in⁴
Column buckling KL/r → Fcr r_x = 5.61 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital corridor beam — c15x33_9

Scenario: Hospital corridor — deflection limit tightened for ceiling and services. Simply supported channel, 32 ft span, 6 ft tributary width. Service loads: 50 psf dead + 80 psf live (780 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (480/12) × (384)⁴ / (384 × 29,000,000 × 315)

Δ_LL = 1.24 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/360):

Δ_allow = L / 360 = 384 / 360 = 1.07 in

Step 3 — Dead + live deflection:

Δ_total = 2.01 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/360 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 191 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.