C8X11.5 Steel C-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 8 203.2 mm
Flange Width (bf) 2.26 5.74 cm
Flange Thickness (tf) 0.39 9.9 mm
Web Thickness (tw) 0.22 5.6 mm
Area (A) 3.37 in² 21.7 cm²
Weight 11.5 lb/ft 17.1 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 32.5 1.31 in⁴
Elastic Section Modulus (S) 8.14 0.775 in³
Plastic Section Modulus (Z) 9.63 1.57 in³
Radius of Gyration (r) 3.11 0.623 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.13 in⁴
Warping Constant (Cw) 16.5 in⁶
Distance Between Flange Centroids (ho) 7.61 in
Effective Radius (rts) 0.756 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 8" deep, this is a compact section commonly specified for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 481.5 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 32.5 in⁴
Torsion St. Venant = GJ/L J = 0.13 in⁴
Column buckling KL/r → Fcr r_x = 3.11 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Parking garage beam — c8x11_5

Scenario: Parking structure floor beam — asphalt topping included in dead load. Simply supported channel, 19 ft span, 9 ft tributary width. Service loads: 80 psf dead + 50 psf live (1170 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (450/12) × (228)⁴ / (384 × 29,000,000 × 32.5)

Δ_LL = 1.40 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 228 / 240 = 0.95 in

Step 3 — Dead + live deflection:

Δ_total = 3.64 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/240 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 36 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.