HP12X53 Steel HP-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 11.8 299.7 mm
Flange Width (bf) 12 30.48 cm
Flange Thickness (tf) 0.435 11.0 mm
Web Thickness (tw) 0.435 11.0 mm
Area (A) 15.5 in² 100.0 cm²
Weight 53 lb/ft 78.9 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 393 127 in⁴
Elastic Section Modulus (S) 66.7 21.1 in³
Plastic Section Modulus (Z) 74 32.2 in³
Radius of Gyration (r) 5.03 2.86 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 1.12 in⁴
Warping Constant (Cw) 4080 in⁶
Distance Between Flange Centroids (ho) 11.4 in
Effective Radius (rts) 3.29 in

Section Profile Summary

This is a standard hot-rolled bearing pile profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 393 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 11.8" deep, this is a compact section well-suited for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 3,700 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 393 in⁴
Torsion St. Venant = GJ/L J = 1.12 in⁴
Column buckling KL/r → Fcr r_x = 5.03 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Bearing Pile Capacity — hp12x53

Scenario: hp12x53 driven to 60 ft depth in medium-dense sand. The pile carries axial compression from a column above. Pile capacity is governed by a combination of geotechnical end bearing + skin friction, plus the structural section capacity.

Given:

Structural capacity (AISC 360 Chapter E):

φPn = 0.9 × Fy × Ag = 0.9 × 50 × 15.5 = 698 kips

The structural capacity typically governs over geotechnical capacity for HP sections in dense soils. Driving stresses should also be checked per PDCA/AASHTO specifications — limit driving stress to 0.9Fy during hard driving conditions.

The final pile capacity must be confirmed by a geotechnical engineer based on site-specific soil conditions, PDA testing, and pile driving records. The structural capacity above is a preliminary estimate only.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.