HP12X74 Steel HP-shape — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 12.1 | 307.3 mm |
| Flange Width (bf) | 12.2 | 30.99 cm |
| Flange Thickness (tf) | 0.61 | 15.5 mm |
| Web Thickness (tw) | 0.605 | 15.4 mm |
| Area (A) | 21.8 in² | 140.6 cmÃÂò |
| Weight | 74 lb/ft | 110.1 kg/m |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 569 | 186 | in⁴ |
| Elastic Section Modulus (S) | 93.8 | 30.4 | in³ |
| Plastic Section Modulus (Z) | 105 | 46.6 | in³ |
| Radius of Gyration (r) | 5.11 | 2.92 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 2.98 | in⁴ |
| Warping Constant (Cw) | 6160 | in⁶ |
| Distance Between Flange Centroids (ho) | 11.5 | in |
| Effective Radius (rts) | 3.38 | in |
Section Profile Summary
This is a standard hot-rolled bearing pile profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 569 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.
At 12.1" deep and 74 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.
Key Design Checks (AISC 360)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 5,250 kip-in |
| Deflection | Δ = 5wLâÃÂô/(384EIx) | Use Ix = 569 in⁴ |
| Torsion | St. Venant = GJ/L | J = 2.98 in⁴ |
| Column buckling | KL/r âÃÂàFcr | r_x = 5.11 in |
Design Notes
- Compactness: Verify flange and web slenderness against AISC 360 Table B4.1 classification limits for the governing load case (pure compression, pure flexure, or combined).
- Combined loading: For members under simultaneous axial force and bending, use the interaction equations in AISC 360 Section H. The governing equation depends on the ratio of required to available axial strength.
- Connection limit states: Check bolt bearing, tear-out, block shear, and weld strength at all connections. The governing connection limit state often controls the member size selection.
Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: Bearing Pile Capacity — hp12x74
Scenario: hp12x74 driven to 60 ft depth in medium-dense sand. The pile carries axial compression from a column above. Pile capacity is governed by a combination of geotechnical end bearing + skin friction, plus the structural section capacity.
Given:
- hp12x74: Ag = 21.8 in²
- Steel: ASTM A572 Gr. 50, Fy = 50 ksi
- Unbraced length below ground: L = 60 ft (fully laterally supported by soil)
Structural capacity (AISC 360 Chapter E):
φPn = 0.9 × Fy × Ag = 0.9 × 50 × 21.8 = 981 kips
The structural capacity typically governs over geotechnical capacity for HP sections in dense soils. Driving stresses should also be checked per PDCA/AASHTO specifications — limit driving stress to 0.9Fy during hard driving conditions.
The final pile capacity must be confirmed by a geotechnical engineer based on site-specific soil conditions, PDA testing, and pile driving records. The structural capacity above is a preliminary estimate only.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.