MC8X8.5 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 8 203.2 mm
Flange Width (bf) 1.87 4.75 cm
Flange Thickness (tf) 0.311 7.9 mm
Web Thickness (tw) 0.179 4.5 mm
Area (A) 2.5 in² 16.1 cm²
Weight 8.5 lb/ft 12.6 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 23.3 0.624 in⁴
Elastic Section Modulus (S) 5.82 0.431 in³
Plastic Section Modulus (Z) 6.95 0.875 in³
Radius of Gyration (r) 3.05 0.5 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.059 in⁴
Warping Constant (Cw) 8.21 in⁶
Distance Between Flange Centroids (ho) 7.69 in
Effective Radius (rts) 0.624 in

Section Profile Summary

The shear center of a channel lies outside the web (distance e₀ from the web face). Loads applied to the top flange produce torsion unless the load plane passes through the shear center. For AISC 360 flexural design, lateral-torsional buckling must be checked with the warping constant Cw.

At 8" deep, this is a compact section commonly specified for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 347.5 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 23.3 in⁴
Torsion St. Venant = GJ/L J = 0.059 in⁴
Column buckling KL/r → Fcr r_x = 3.05 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Roof beam (flat roof) — mc8x8_5

Scenario: Flat roof beam with mechanical unit allowance — drainage slope not included. Simply supported channel, 16 ft span, 6 ft tributary width. Service loads: 25 psf dead + 20 psf live (270 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (120/12) × (192)⁴ / (384 × 29,000,000 × 23.3)

Δ_LL = 0.26 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 192 / 240 = 0.80 in

Step 3 — Dead + live deflection:

Δ_total = 0.59 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 26 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.