MC8X22.8 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 8 203.2 mm
Flange Width (bf) 3.5 8.89 cm
Flange Thickness (tf) 0.525 13.3 mm
Web Thickness (tw) 0.427 10.8 mm
Area (A) 6.7 in² 43.2 cm²
Weight 22.8 lb/ft 33.9 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 63.8 7.01 in⁴
Elastic Section Modulus (S) 15.9 2.81 in³
Plastic Section Modulus (Z) 19.1 5.37 in³
Radius of Gyration (r) 3.09 1.02 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.572 in⁴
Warping Constant (Cw) 75.2 in⁶
Distance Between Flange Centroids (ho) 7.48 in
Effective Radius (rts) 1.2 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 8" deep, this is a compact section commonly specified for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 955 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 63.8 in⁴
Torsion St. Venant = GJ/L J = 0.572 in⁴
Column buckling KL/r → Fcr r_x = 3.09 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital corridor beam — mc8x22_8

Scenario: Hospital corridor — deflection limit tightened for ceiling and services. Simply supported channel, 17 ft span, 6 ft tributary width. Service loads: 50 psf dead + 80 psf live (780 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (480/12) × (204)⁴ / (384 × 29,000,000 × 63.8)

Δ_LL = 0.49 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/360):

Δ_allow = L / 360 = 204 / 360 = 0.57 in

Step 3 — Dead + live deflection:

Δ_total = 0.79 in

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 72 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.