S10X35 Steel S-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 10 254.0 mm
Flange Width (bf) 4.94 12.55 cm
Flange Thickness (tf) 0.491 12.5 mm
Web Thickness (tw) 0.594 15.1 mm
Area (A) 10.3 in² 66.5 cm²
Weight 35 lb/ft 52.1 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 147 8.3 in⁴
Elastic Section Modulus (S) 29.4 3.36 in³
Plastic Section Modulus (Z) 35.4 6.19 in³
Radius of Gyration (r) 3.78 0.899 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 1.29 in⁴
Warping Constant (Cw) 188 in⁶
Distance Between Flange Centroids (ho) 9.51 in
Effective Radius (rts) 1.16 in

Section Profile Summary

This is a standard hot-rolled I-beam profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 147 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 10" deep, this is a compact section a practical choice for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 1,770 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 147 in⁴
Torsion St. Venant = GJ/L J = 1.29 in⁴
Column buckling KL/r → Fcr r_x = 3.78 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Roof beam (flat roof) — s10x35

Scenario: Flat roof beam with mechanical unit allowance — drainage slope not included. Simply supported I-beam, 23 ft span, 6 ft tributary width. Service loads: 25 psf dead + 20 psf live (270 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (120/12) × (276)⁴ / (384 × 29,000,000 × 147)

Δ_LL = 0.18 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 276 / 240 = 1.15 in

Step 3 — Dead + live deflection:

Δ_total = 0.40 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 133 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.