S12X35 Steel S-shape — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 12 | 304.8 mm |
| Flange Width (bf) | 5.08 | 12.90 cm |
| Flange Thickness (tf) | 0.544 | 13.8 mm |
| Web Thickness (tw) | 0.428 | 10.9 mm |
| Area (A) | 10.2 in² | 65.8 cmÃÂò |
| Weight | 35 lb/ft | 52.1 kg/m |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 228 | 9.84 | in⁴ |
| Elastic Section Modulus (S) | 38.1 | 3.88 | in³ |
| Plastic Section Modulus (Z) | 44.6 | 6.8 | in³ |
| Radius of Gyration (r) | 4.72 | 0.98 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 1.05 | in⁴ |
| Warping Constant (Cw) | 323 | in⁶ |
| Distance Between Flange Centroids (ho) | 11.5 | in |
| Effective Radius (rts) | 1.22 | in |
Section Profile Summary
This is a standard hot-rolled I-beam profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 228 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.
At 12" deep, this is a compact section a practical choice for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.
Key Design Checks (AISC 360)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 2,230 kip-in |
| Deflection | Δ = 5wLâÃÂô/(384EIx) | Use Ix = 228 in⁴ |
| Torsion | St. Venant = GJ/L | J = 1.05 in⁴ |
| Column buckling | KL/r âÃÂàFcr | r_x = 4.72 in |
Design Notes
- Compactness: Verify flange and web slenderness against AISC 360 Table B4.1 classification limits for the governing load case (pure compression, pure flexure, or combined).
- Combined loading: For members under simultaneous axial force and bending, use the interaction equations in AISC 360 Section H. The governing equation depends on the ratio of required to available axial strength.
- Connection limit states: Check bolt bearing, tear-out, block shear, and weld strength at all connections. The governing connection limit state often controls the member size selection.
Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: Assembly hall floor beam — s12x35
Scenario: Public assembly space — higher live load for movable seating/standing. Simply supported I-beam, 24 ft span, 8 ft tributary width. Service loads: 60 psf dead + 100 psf live (1280 plf total).
Given:
- Span L = 24 ft (288 in)
- Total service load w = 1280 plf
- Live load portion w_L = 800 plf
- Section s12x35: Ix = 228 in⁴, Sx = 38.1 in³, Zx = 44.6 in³
- Steel: ASTM A992, Fy = 50 ksi, E = 29,000 ksi
- Design moment strength: φMn = 0.9 × Zx × Fy = 167 kip-ft
Step 1 — Live load deflection check:
Δ_LL = 5 w_L LâÃÂô / (384 E Ix)
Δ_LL = 5 × (800/12) × (288)âÃÂô / (384 × 29,000,000 × 228)
Δ_LL = 0.90 in
Step 2 — Allowable deflection (IBC Table 1604.3, L/240):
Δ_allow = L / 240 = 288 / 240 = 1.20 in
Step 3 — Dead + live deflection:
Δ_total = 1.45 in
Step 4 — Design check:
âÃÂàLive load deflection is within the L/240 limit.
The required flexural strength at ultimate is approximately w_u LÃÂò/8. With factored loads 1.2D + 1.6L, verify φMn = 167 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.