W14X370 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 17.90 in (454.7 mm)
Flange Width (bf) 16.50 in (419.1 mm)
Flange Thickness (tf) 2.66 in
Web Thickness (tw) 1.66 in
Area (A) 109 in² (703.3 cm²)
Weight 370 lb/ft (551 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 5,440 1,990 in⁴
Elastic Section Modulus (S) 607 241 in³
Plastic Section Modulus (Z) 736 370 in³
Radius of Gyration (r) 7.07 4.27 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 222 in⁴
Warping Constant (Cw) 116,000 in⁶
Distance Between Flange Centroids (ho) 15.20 in
Effective Radius (rts) 5 in

Section Profile Summary

Hot-rolled W-shape with Sx = 607 in³. The section is suitable for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 17.9" deep and 370 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 36,800 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 5,440 in⁴
Torsion St. Venant = GJ/L J = 222 in⁴
Column buckling KL/r → Fcr r_x = 7.07 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Assembly hall floor beam — w14x370

Scenario: Public assembly space — higher live load for movable seating/standing. Simply supported wide flange, 30 ft span, 8 ft tributary width. Service loads: 60 psf dead + 100 psf live (1280 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (800/12) × (360)⁴ / (384 × 29,000,000 × 5,440)

Δ_LL = 0.09 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 360 / 240 = 1.50 in

Step 3 — Dead + live deflection:

Δ_total = 0.15 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 2,760 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.