W14X398 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 18.30 in (464.8 mm)
Flange Width (bf) 16.60 in (421.6 mm)
Flange Thickness (tf) 2.85 in
Web Thickness (tw) 1.77 in
Area (A) 117 in² (754.9 cm²)
Weight 398 lb/ft (592 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 6,000 2,170 in⁴
Elastic Section Modulus (S) 656 262 in³
Plastic Section Modulus (Z) 801 402 in³
Radius of Gyration (r) 7.16 4.31 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 273 in⁴
Warping Constant (Cw) 129,000 in⁶
Distance Between Flange Centroids (ho) 15.50 in
Effective Radius (rts) 5.05 in

Section Profile Summary

Hot-rolled W-shape with Sx = 656 in³. The section is well-suited for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 18.3" deep and 398 lb/ft, this is a mid-range section suitable for floor beams, roof framing, and columns in low-to-mid-rise structures.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 40,050 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 6,000 in⁴
Torsion St. Venant = GJ/L J = 273 in⁴
Column buckling KL/r → Fcr r_x = 7.16 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — w14x398

Scenario: Office floor in a commercial building — typical open-plan layout. Simply supported wide flange, 37 ft span, 8 ft tributary width. Service loads: 50 psf dead + 50 psf live (800 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (400/12) × (444)⁴ / (384 × 29,000,000 × 6,000)

Δ_LL = 0.10 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 444 / 240 = 1.85 in

Step 3 — Dead + live deflection:

Δ_total = 0.19 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 3,004 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.