W24X76 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 23.90 in (607.1 mm)
Flange Width (bf) 8.99 in (228.3 mm)
Flange Thickness (tf) 0.68 in
Web Thickness (tw) 0.44 in
Area (A) 22.40 in² (144.5 cm²)
Weight 76 lb/ft (113 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 2,100 82.50 in⁴
Elastic Section Modulus (S) 176 18.40 in³
Plastic Section Modulus (Z) 200 28.60 in³
Radius of Gyration (r) 9.69 1.92 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 2.68 in⁴
Warping Constant (Cw) 11,100 in⁶
Distance Between Flange Centroids (ho) 23.20 in
Effective Radius (rts) 2.33 in

Section Profile Summary

With Ix = 2,100 in⁴, this wide flange is a practical choice for long-span floor beams and transfer girders where stiffness controls the design.

At 23.9" deep, this section is frequently specified for primary floor beams, girders, and moment frame columns in commercial and institutional buildings.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 10,000 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 2,100 in⁴
Torsion St. Venant = GJ/L J = 2.68 in⁴
Column buckling KL/r → Fcr r_x = 9.69 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Assembly hall floor beam — w24x76

Scenario: Public assembly space — higher live load for movable seating/standing. Simply supported wide flange, 48 ft span, 8 ft tributary width. Service loads: 60 psf dead + 100 psf live (1280 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (800/12) × (576)⁴ / (384 × 29,000,000 × 2,100)

Δ_LL = 1.57 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 576 / 240 = 2.40 in

Step 3 — Dead + live deflection:

Δ_total = 2.51 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 750 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.