W36X330 Steel Beam — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 37.70 | in (957.6 mm) |
| Flange Width (bf) | 16.60 | in (421.6 mm) |
| Flange Thickness (tf) | 1.85 | in |
| Web Thickness (tw) | 1.02 | in |
| Area (A) | 96.90 | in² (625.2 cm²) |
| Weight | 330 | lb/ft (491 kg/m) |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 23,300 | 1,420 | in⁴ |
| Elastic Section Modulus (S) | 1,240 | 171 | in³ |
| Plastic Section Modulus (Z) | 1,410 | 265 | in³ |
| Radius of Gyration (r) | 15.50 | 3.83 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 84.30 | in⁴ |
| Warping Constant (Cw) | 456,000 | in⁶ |
| Distance Between Flange Centroids (ho) | 35.90 | in |
| Effective Radius (rts) | 4.53 | in |
Design Resources
- Beam Capacity Calculator — Check W36X330 for your span and loads
- Column Capacity Calculator — Check W36X330 as a column
- Section Properties Database — Compare with other sections
- Steel Beam Sizes Reference — Full W-shape dimension table
- Steel Grades Reference — A992/A572 material properties
Frequently Asked Questions
What is the weight of a W36X330 beam? 330 lb/ft (491 kg/m). A 40-ft length weighs approximately 13,200 lbs.
What is the section modulus of W36X330? Sx = 1240 in³ (strong axis) and Sy = 171 in³ (weak axis). The plastic section modulus Zx = 1410 in³ and Zy = 265 in³.
What steel grade is standard for W36X330? Typically ASTM A992 (Fy = 50 ksi, Fu = 65 ksi) for W-shapes. Also available in A572 Grade 50 or A36. Verify with mill certificate.
What is the moment of inertia of W36X330? Ix = 23300 in⁴ about the strong axis and Iy = 1420 in⁴ about the weak axis. The radius of gyration is rx = 15.50 in and ry = 3.83 in.
Related Pages
- Steel Beam Sizes Reference
- Beam Capacity Calculator
- Column Capacity Calculator
- Section Properties Database
Educational reference only. Verify all section properties against the current AISC Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.