W36X361 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 38 in (965.2 mm)
Flange Width (bf) 16.70 in (424.2 mm)
Flange Thickness (tf) 2.01 in
Web Thickness (tw) 1.12 in
Area (A) 106 in² (683.9 cm²)
Weight 361 lb/ft (537 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 25,700 1,570 in⁴
Elastic Section Modulus (S) 1,350 188 in³
Plastic Section Modulus (Z) 1,550 293 in³
Radius of Gyration (r) 15.60 3.85 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 109 in⁴
Warping Constant (Cw) 509,000 in⁶
Distance Between Flange Centroids (ho) 36 in
Effective Radius (rts) 4.58 in

Section Profile Summary

Hot-rolled W-shape with Sx = 1,350 in³. The section is appropriate for primary framing in multi-storey buildings, crane girders, and bridge stringers.

At 38" deep and 361 lb/ft, this is a heavy section typically reserved for transfer girders, long-span roof trusses, and heavily loaded columns in high-rise construction. Shipping and handling require crane erection planning.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 77,500 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 25,700 in⁴
Torsion St. Venant = GJ/L J = 109 in⁴
Column buckling KL/r → Fcr r_x = 15.6 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Library stack beam — w36x361

Scenario: Library stack area — dead load includes shelving and books. Simply supported wide flange, 60 ft span, 7 ft tributary width. Service loads: 85 psf dead + 60 psf live (1015 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (420/12) × (720)⁴ / (384 × 29,000,000 × 25,700)

Δ_LL = 0.16 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 720 / 240 = 3.00 in

Step 3 — Dead + live deflection:

Δ_total = 0.40 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 5,813 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.