W5X16 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 5.01 in (127.3 mm)
Flange Width (bf) 5 in (127.0 mm)
Flange Thickness (tf) 0.36 in
Web Thickness (tw) 0.24 in
Area (A) 4.71 in² (30.4 cm²)
Weight 16 lb/ft (24 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 21.40 7.51 in⁴
Elastic Section Modulus (S) 8.55 3 in³
Plastic Section Modulus (Z) 9.63 4.58 in³
Radius of Gyration (r) 2.13 1.26 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.19 in⁴
Warping Constant (Cw) 40.60 in⁶
Distance Between Flange Centroids (ho) 4.65 in
Effective Radius (rts) 1.43 in

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 21.4 in⁴, the strong-axis stiffness places it in the light beam category for preliminary sizing.

At 5.01" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 481.5 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 21.4 in⁴
Torsion St. Venant = GJ/L J = 0.19 in⁴
Column buckling KL/r → Fcr r_x = 2.13 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — w5x16

Scenario: Office floor in a commercial building — typical open-plan layout. Simply supported wide flange, 10 ft span, 8 ft tributary width. Service loads: 50 psf dead + 50 psf live (800 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (400/12) × (120)⁴ / (384 × 29,000,000 × 21.4)

Δ_LL = 0.15 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 120 / 240 = 0.50 in

Step 3 — Dead + live deflection:

Δ_total = 0.29 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 36 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.