W6X12 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 6.03 in (153.2 mm)
Flange Width (bf) 4 in (101.6 mm)
Flange Thickness (tf) 0.28 in
Web Thickness (tw) 0.23 in
Area (A) 3.55 in² (22.9 cm²)
Weight 12 lb/ft (18 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 22.10 2.99 in⁴
Elastic Section Modulus (S) 7.31 1.50 in³
Plastic Section Modulus (Z) 8.30 2.32 in³
Radius of Gyration (r) 2.49 0.92 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.09 in⁴
Warping Constant (Cw) 24.70 in⁶
Distance Between Flange Centroids (ho) 5.75 in
Effective Radius (rts) 1.08 in

Section Profile Summary

A wide flange with parallel flange faces — makes bolted and welded connections straightforward to detail. At Ix = 22.1 in⁴, the strong-axis stiffness places it in the light beam category for preliminary sizing.

At 6.03" deep, this is a compact section commonly specified for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 415 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 22.1 in⁴
Torsion St. Venant = GJ/L J = 0.09 in⁴
Column buckling KL/r → Fcr r_x = 2.49 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital corridor beam — w6x12

Scenario: Hospital corridor — deflection limit tightened for ceiling and services. Simply supported wide flange, 10 ft span, 6 ft tributary width. Service loads: 50 psf dead + 80 psf live (780 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (480/12) × (120)⁴ / (384 × 29,000,000 × 22.1)

Δ_LL = 0.17 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/360):

Δ_allow = L / 360 = 120 / 360 = 0.33 in

Step 3 — Dead + live deflection:

Δ_total = 0.27 in

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 31 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.