W8X13 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 7.99 in (202.9 mm)
Flange Width (bf) 4 in (101.6 mm)
Flange Thickness (tf) 0.26 in
Web Thickness (tw) 0.23 in
Area (A) 3.84 in² (24.8 cm²)
Weight 13 lb/ft (19 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 39.60 2.73 in⁴
Elastic Section Modulus (S) 9.91 1.37 in³
Plastic Section Modulus (Z) 11.40 2.15 in³
Radius of Gyration (r) 3.21 0.84 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.09 in⁴
Warping Constant (Cw) 40.80 in⁶
Distance Between Flange Centroids (ho) 7.74 in
Effective Radius (rts) 1.03 in

Section Profile Summary

With Ix = 39.6 in⁴, this wide flange is appropriate for short-span beams, lintels, and secondary framing members.

At 7.99" deep, this is a compact section appropriate for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 570 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 39.6 in⁴
Torsion St. Venant = GJ/L J = 0.09 in⁴
Column buckling KL/r → Fcr r_x = 3.21 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — w8x13

Scenario: Office floor in a commercial building — typical open-plan layout. Simply supported wide flange, 13 ft span, 8 ft tributary width. Service loads: 50 psf dead + 50 psf live (800 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (400/12) × (156)⁴ / (384 × 29,000,000 × 39.6)

Δ_LL = 0.22 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 156 / 240 = 0.65 in

Step 3 — Dead + live deflection:

Δ_total = 0.45 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 43 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.