W8X18 Steel Beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 8.14 in (206.8 mm)
Flange Width (bf) 5.25 in (133.3 mm)
Flange Thickness (tf) 0.33 in
Web Thickness (tw) 0.23 in
Area (A) 5.26 in² (33.9 cm²)
Weight 18 lb/ft (27 kg/m)

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 61.90 7.97 in⁴
Elastic Section Modulus (S) 15.20 3.04 in³
Plastic Section Modulus (Z) 17 4.66 in³
Radius of Gyration (r) 3.43 1.23 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.17 in⁴
Warping Constant (Cw) 122 in⁶
Distance Between Flange Centroids (ho) 7.81 in
Effective Radius (rts) 1.43 in

Section Profile Summary

With Ix = 61.9 in⁴, this wide flange is appropriate for short-span beams, lintels, and secondary framing members.

At 8.14" deep, this is a compact section appropriate for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 850 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 61.9 in⁴
Torsion St. Venant = GJ/L J = 0.17 in⁴
Column buckling KL/r → Fcr r_x = 3.43 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital corridor beam — w8x18

Scenario: Hospital corridor — deflection limit tightened for ceiling and services. Simply supported wide flange, 19 ft span, 6 ft tributary width. Service loads: 50 psf dead + 80 psf live (780 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (480/12) × (228)⁴ / (384 × 29,000,000 × 61.9)

Δ_LL = 0.78 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/360):

Δ_allow = L / 360 = 228 / 360 = 0.63 in

Step 3 — Dead + live deflection:

Δ_total = 1.27 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/360 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 64 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.