M3X2.9 Steel Miscellaneous beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 3 76.2 mm
Flange Width (bf) 2.25 5.71 cm
Flange Thickness (tf) 0.13 3.3 mm
Web Thickness (tw) 0.09 2.3 mm
Area (A) 0.914 in² 5.9 cm²
Weight 2.9 lb/ft 4.3 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 1.5 0.248 in⁴
Elastic Section Modulus (S) 1 0.221 in³
Plastic Section Modulus (Z) 1.12 0.344 in³
Radius of Gyration (r) 1.28 0.521 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.008 in⁴
Warping Constant (Cw) 0.511 in⁶
Distance Between Flange Centroids (ho) 2.87 in
Effective Radius (rts) 0.597 in

Section Profile Summary

This is a standard hot-rolled light I-beam profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 1.5 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 3" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 56 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 1.5 in⁴
Torsion St. Venant = GJ/L J = 0.008 in⁴
Column buckling KL/r → Fcr r_x = 1.28 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Light commercial floor beam — m3x2_9

Scenario: Retail space floor — higher live load for public occupancy. Simply supported light I-beam, 10 ft span, 8 ft tributary width. Service loads: 55 psf dead + 60 psf live (920 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (480/12) × (120)⁴ / (384 × 29,000,000 × 1.5)

Δ_LL = 2.48 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 120 / 240 = 0.50 in

Step 3 — Dead + live deflection:

Δ_total = 4.76 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/240 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 4 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.