M4X4.08 Steel Miscellaneous beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 4 101.6 mm
Flange Width (bf) 2.25 5.71 cm
Flange Thickness (tf) 0.17 4.3 mm
Web Thickness (tw) 0.115 2.9 mm
Area (A) 1.27 in² 8.2 cm²
Weight 4.08 lb/ft 6.1 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 3.53 0.325 in⁴
Elastic Section Modulus (S) 1.77 0.289 in³
Plastic Section Modulus (Z) 2 0.453 in³
Radius of Gyration (r) 1.67 0.506 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.015 in⁴
Warping Constant (Cw) 1.19 in⁶
Distance Between Flange Centroids (ho) 3.83 in
Effective Radius (rts) 0.593 in

Section Profile Summary

This is a standard hot-rolled light I-beam profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 3.53 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 4" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 100 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 3.53 in⁴
Torsion St. Venant = GJ/L J = 0.015 in⁴
Column buckling KL/r → Fcr r_x = 1.67 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Parking garage beam — m4x4_08

Scenario: Parking structure floor beam — asphalt topping included in dead load. Simply supported light I-beam, 10 ft span, 9 ft tributary width. Service loads: 80 psf dead + 50 psf live (1170 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (450/12) × (120)⁴ / (384 × 29,000,000 × 3.53)

Δ_LL = 0.99 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 120 / 240 = 0.50 in

Step 3 — Dead + live deflection:

Δ_total = 2.57 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/240 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 8 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.