M4X6 Steel Miscellaneous beam — Section Properties

Dimensions

Property Value Unit
Depth (d) 3.8 96.5 mm
Flange Width (bf) 3.8 9.65 cm
Flange Thickness (tf) 0.16 4.1 mm
Web Thickness (tw) 0.13 3.3 mm
Area (A) 1.75 in² 11.3 cm²
Weight 6 lb/ft 8.9 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 4.72 1.47 in⁴
Elastic Section Modulus (S) 2.48 0.771 in³
Plastic Section Modulus (Z) 2.74 1.18 in³
Radius of Gyration (r) 1.64 0.915 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.018 in⁴
Warping Constant (Cw) 4.87 in⁶
Distance Between Flange Centroids (ho) 3.64 in
Effective Radius (rts) 1.04 in

Section Profile Summary

This is a standard hot-rolled light I-beam profile covered by AISC 360. The tabulated section properties are computed from the nominal dimensions per the governing material standard. With Ix = 4.72 in⁴, the strong-axis flexural stiffness is suitable for preliminary sizing of beams and beam-columns.

At 3.8" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 137 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 4.72 in⁴
Torsion St. Venant = GJ/L J = 0.018 in⁴
Column buckling KL/r → Fcr r_x = 1.64 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Assembly hall floor beam — m4x6

Scenario: Public assembly space — higher live load for movable seating/standing. Simply supported light I-beam, 10 ft span, 8 ft tributary width. Service loads: 60 psf dead + 100 psf live (1280 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (800/12) × (120)⁴ / (384 × 29,000,000 × 4.72)

Δ_LL = 1.32 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 120 / 240 = 0.50 in

Step 3 — Dead + live deflection:

Δ_total = 2.10 in

Step 4 — Design check:

⚠ Live load deflection exceeds L/240 — consider a deeper section, reduce tributary width, or shorten the span.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 10 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.