MC6X18 Steel MC-shape — Section Properties
Dimensions
| Property | Value | Unit |
|---|---|---|
| Depth (d) | 6 | 152.4 mm |
| Flange Width (bf) | 3.5 | 8.89 cm |
| Flange Thickness (tf) | 0.475 | 12.1 mm |
| Web Thickness (tw) | 0.379 | 9.6 mm |
| Area (A) | 5.29 in² | 34.1 cmÃÂò |
| Weight | 18 lb/ft | 26.8 kg/m |
Elastic Section Properties
| Property | Strong Axis (X-X) | Weak Axis (Y-Y) | Unit |
|---|---|---|---|
| Moment of Inertia (I) | 29.7 | 5.88 | in⁴ |
| Elastic Section Modulus (S) | 9.89 | 2.47 | in³ |
| Plastic Section Modulus (Z) | 11.7 | 4.68 | in³ |
| Radius of Gyration (r) | 2.37 | 1.05 | in |
Torsional Properties
| Property | Value | Unit |
|---|---|---|
| Torsional Constant (J) | 0.379 | in⁴ |
| Warping Constant (Cw) | 34.6 | in⁶ |
| Distance Between Flange Centroids (ho) | 5.53 | in |
| Effective Radius (rts) | 1.2 | in |
Section Profile Summary
Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.
At 6" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.
Key Design Checks (AISC 360)
| Check | Formula | This Section |
|---|---|---|
| Plastic moment | Mp = Zx × Fy | 585 kip-in |
| Deflection | Δ = 5wLâÃÂô/(384EIx) | Use Ix = 29.7 in⁴ |
| Torsion | St. Venant = GJ/L | J = 0.379 in⁴ |
| Column buckling | KL/r âÃÂàFcr | r_x = 2.37 in |
Design Notes
- Section asymmetry: The shear center lies outside the web. Loads not applied through the shear center produce torsion. Provide intermediate torsional restraints or stiffeners when the load eccentricity is significant.
- Lateral-torsional buckling: Check Cb (moment modification factor) per AISC 360 Chapter F — channels are more sensitive to load height effects than doubly-symmetric sections.
- Web crippling at supports: For channels used as beams, bearing stiffeners may be needed at concentrated load points per AISC 360 Section J10.
Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.
Worked Example: Parking garage beam — mc6x18
Scenario: Parking structure floor beam — asphalt topping included in dead load. Simply supported channel, 10 ft span, 9 ft tributary width. Service loads: 80 psf dead + 50 psf live (1170 plf total).
Given:
- Span L = 10 ft (120 in)
- Total service load w = 1170 plf
- Live load portion w_L = 450 plf
- Section mc6x18: Ix = 29.7 in⁴, Sx = 9.89 in³, Zx = 11.7 in³
- Steel: ASTM A992, Fy = 50 ksi, E = 29,000 ksi
- Design moment strength: φMn = 0.9 × Zx × Fy = 44 kip-ft
Step 1 — Live load deflection check:
Δ_LL = 5 w_L LâÃÂô / (384 E Ix)
Δ_LL = 5 × (450/12) × (120)âÃÂô / (384 × 29,000,000 × 29.7)
Δ_LL = 0.12 in
Step 2 — Allowable deflection (IBC Table 1604.3, L/240):
Δ_allow = L / 240 = 120 / 240 = 0.50 in
Step 3 — Dead + live deflection:
Δ_total = 0.31 in
Step 4 — Design check:
âÃÂàLive load deflection is within the L/240 limit.
The required flexural strength at ultimate is approximately w_u LÃÂò/8. With factored loads 1.2D + 1.6L, verify φMn = 44 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.
Related Resources
- Steel Beam Capacity Calculator
- Column Capacity Calculator
- Beam Deflection Calculator
- Section Properties Calculator
- Steel Grades Reference
- Section Comparison Tool
Design Resources
- Section Properties Lookup — Compare with similar sections
- Steel Beam Sizes Reference — Standard beam dimensions
Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.