MC6X7 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 6 152.4 mm
Flange Width (bf) 1.88 4.78 cm
Flange Thickness (tf) 0.291 7.4 mm
Web Thickness (tw) 0.179 4.5 mm
Area (A) 2.09 in² 13.5 cm²
Weight 7 lb/ft 10.4 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 11.4 0.603 in⁴
Elastic Section Modulus (S) 3.81 0.439 in³
Plastic Section Modulus (Z) 4.5 0.865 in³
Radius of Gyration (r) 2.34 0.537 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.046 in⁴
Warping Constant (Cw) 4 in⁶
Distance Between Flange Centroids (ho) 5.71 in
Effective Radius (rts) 0.638 in

Section Profile Summary

The shear center of a channel lies outside the web (distance e₀ from the web face). Loads applied to the top flange produce torsion unless the load plane passes through the shear center. For AISC 360 flexural design, lateral-torsional buckling must be checked with the warping constant Cw.

At 6" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 225 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 11.4 in⁴
Torsion St. Venant = GJ/L J = 0.046 in⁴
Column buckling KL/r → Fcr r_x = 2.34 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Hospital corridor beam — mc6x7

Scenario: Hospital corridor — deflection limit tightened for ceiling and services. Simply supported channel, 10 ft span, 6 ft tributary width. Service loads: 50 psf dead + 80 psf live (780 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (480/12) × (120)⁴ / (384 × 29,000,000 × 11.4)

Δ_LL = 0.33 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/360):

Δ_allow = L / 360 = 120 / 360 = 0.33 in

Step 3 — Dead + live deflection:

Δ_total = 0.53 in

Step 4 — Design check:

✓ Live load deflection is within the L/360 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 17 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.