Dimensions

Property Value Unit
Depth (d) 6 152.4 mm
Flange Width (bf) 1.85 4.70 cm
Flange Thickness (tf) 0.291 7.4 mm
Web Thickness (tw) 0.155 3.9 mm
Area (A) 1.95 in² 12.6 cm²
Weight 6.5 lb/ft 9.7 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 11 0.565 in⁴
Elastic Section Modulus (S) 3.66 0.422 in³
Plastic Section Modulus (Z) 4.28 0.836 in³
Radius of Gyration (r) 2.38 0.539 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.041 in⁴
Warping Constant (Cw) 3.75 in⁶
Distance Between Flange Centroids (ho) 5.71 in
Effective Radius (rts) 0.631 in

Section Profile Summary

Channels are efficient for bracing, girts, and stair stringers where loads align near the shear center. At 6.5 lb/ft, this channel is suitable for secondary framing in industrial and commercial structures.

At 6" deep — one of the smallest standard sections available. Used for light-duty lintels, bracing, handrail posts, and miscellaneous structural iron.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 214 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 11 in⁴
Torsion St. Venant = GJ/L J = 0.041 in⁴
Column buckling KL/r → Fcr r_x = 2.38 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Office floor beam — mc6x6_5

Scenario: Office floor in a commercial building — typical open-plan layout. Simply supported channel, 10 ft span, 8 ft tributary width. Service loads: 50 psf dead + 50 psf live (800 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (400/12) × (120)⁴ / (384 × 29,000,000 × 11)

Δ_LL = 0.28 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 120 / 240 = 0.50 in

Step 3 — Dead + live deflection:

Δ_total = 0.56 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 16 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.