MC8X18.7 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 8 203.2 mm
Flange Width (bf) 2.98 7.57 cm
Flange Thickness (tf) 0.5 12.7 mm
Web Thickness (tw) 0.353 9.0 mm
Area (A) 5.5 in² 35.5 cm²
Weight 18.7 lb/ft 27.8 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 52.4 4.15 in⁴
Elastic Section Modulus (S) 13.1 1.95 in³
Plastic Section Modulus (Z) 15.6 3.72 in³
Radius of Gyration (r) 3.09 0.868 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.38 in⁴
Warping Constant (Cw) 45 in⁶
Distance Between Flange Centroids (ho) 7.5 in
Effective Radius (rts) 1.02 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 8" deep, this is a compact section suitable for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 780 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 52.4 in⁴
Torsion St. Venant = GJ/L J = 0.38 in⁴
Column buckling KL/r → Fcr r_x = 3.09 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Warehouse mezzanine beam — mc8x18_7

Scenario: Mezzanine beam in a warehouse — storage live load governs design. Simply supported channel, 13 ft span, 5 ft tributary width. Service loads: 30 psf dead + 125 psf live (775 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (625/12) × (156)⁴ / (384 × 29,000,000 × 52.4)

Δ_LL = 0.26 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 156 / 240 = 0.65 in

Step 3 — Dead + live deflection:

Δ_total = 0.33 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 59 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.