MC7X19.1 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 7 177.8 mm
Flange Width (bf) 3.45 8.76 cm
Flange Thickness (tf) 0.5 12.7 mm
Web Thickness (tw) 0.352 8.9 mm
Area (A) 5.61 in² 36.2 cm²
Weight 19.1 lb/ft 28.4 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 43.1 6.06 in⁴
Elastic Section Modulus (S) 12.3 2.55 in³
Plastic Section Modulus (Z) 14.5 4.85 in³
Radius of Gyration (r) 2.77 1.04 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.407 in⁴
Warping Constant (Cw) 49.3 in⁶
Distance Between Flange Centroids (ho) 6.5 in
Effective Radius (rts) 1.19 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 7" deep, this is a compact section appropriate for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 725 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 43.1 in⁴
Torsion St. Venant = GJ/L J = 0.407 in⁴
Column buckling KL/r → Fcr r_x = 2.77 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Assembly hall floor beam — mc7x19_1

Scenario: Public assembly space — higher live load for movable seating/standing. Simply supported channel, 15 ft span, 8 ft tributary width. Service loads: 60 psf dead + 100 psf live (1280 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (800/12) × (180)⁴ / (384 × 29,000,000 × 43.1)

Δ_LL = 0.73 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 180 / 240 = 0.75 in

Step 3 — Dead + live deflection:

Δ_total = 1.17 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 54 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.

Related Resources

Design Resources


Educational reference only. Verify all section properties against the current AISC 360 Manual and mill certificates before design. Results are PRELIMINARY — NOT FOR CONSTRUCTION.