MC8X20 Steel MC-shape — Section Properties

Dimensions

Property Value Unit
Depth (d) 8 203.2 mm
Flange Width (bf) 3.03 7.70 cm
Flange Thickness (tf) 0.5 12.7 mm
Web Thickness (tw) 0.4 10.2 mm
Area (A) 5.87 in² 37.9 cm²
Weight 20 lb/ft 29.8 kg/m

Elastic Section Properties

Property Strong Axis (X-X) Weak Axis (Y-Y) Unit
Moment of Inertia (I) 54.4 4.42 in⁴
Elastic Section Modulus (S) 13.6 2.02 in³
Plastic Section Modulus (Z) 16.4 3.86 in³
Radius of Gyration (r) 3.04 0.867 in

Torsional Properties

Property Value Unit
Torsional Constant (J) 0.441 in⁴
Warping Constant (Cw) 47.8 in⁶
Distance Between Flange Centroids (ho) 7.5 in
Effective Radius (rts) 1.03 in

Section Profile Summary

Unlike doubly-symmetric sections, channel bending about the weak axis produces twist. Where weak-axis flexure is unavoidable, provide torsional restraint at close intervals or switch to a hollow section.

At 8" deep, this is a compact section a practical choice for joists, mezzanine framing, equipment support beams, and architectural features where depth control matters.

Key Design Checks (AISC 360)

Check Formula This Section
Plastic moment Mp = Zx × Fy 820 kip-in
Deflection Δ = 5wL⁴/(384EIx) Use Ix = 54.4 in⁴
Torsion St. Venant = GJ/L J = 0.441 in⁴
Column buckling KL/r → Fcr r_x = 3.04 in

Design Notes

Verification (AISC 360): All designs using this section must be verified by a licensed Professional Engineer. Before finalizing member selection, check beam-column interaction (P-M), lateral-torsional buckling, serviceability deflections, and all connection limit states. See Engineering Disclaimer.

Worked Example: Library stack beam — mc8x20

Scenario: Library stack area — dead load includes shelving and books. Simply supported channel, 14 ft span, 7 ft tributary width. Service loads: 85 psf dead + 60 psf live (1015 plf total).

Given:

Step 1 — Live load deflection check:

Δ_LL = 5 w_L L⁴ / (384 E Ix)

Δ_LL = 5 × (420/12) × (168)⁴ / (384 × 29,000,000 × 54.4)

Δ_LL = 0.23 in

Step 2 — Allowable deflection (IBC Table 1604.3, L/240):

Δ_allow = L / 240 = 168 / 240 = 0.70 in

Step 3 — Dead + live deflection:

Δ_total = 0.56 in

Step 4 — Design check:

✓ Live load deflection is within the L/240 limit.

The required flexural strength at ultimate is approximately w_u L²/8. With factored loads 1.2D + 1.6L, verify φMn = 61 kip-ft is adequate per AISC 360 Chapter F. Also check shear capacity (φVn = 0.6 Fy Aw × 0.9) and bearing at supports.